Maxim Integrated DS21Q55 User Manual
Page 179

Product Preview
DS21Q55
179 of 248
012103
Please contact
or search
http://www.maxim-ic.com
for updated
information.
Register Name:
BC2
Register Description:
BERT Control Register 2
Register Address:
E1h
Bit #
7
6
5
4
3
2
1
0
Name
EIB2
EIB1
EIB0
SBE
RPL3
RPL2
RPL1
RPL0
Default
0
0
0
0
0
0
0
0
Bits 0 to 3/Repetitive Pattern Length Bit 3 (RPL0 to RPL3). RPL0 is the LSB and RPL3 is the MSB of a nibble that
describes the how long the repetitive pattern is. The valid range is 17 (0000) to 32 (1111). These bits are ignored if the receive
BERT is programmed for a pseudorandom pattern. To create repetitive patterns less than 17 bits in length, the user must set the
length to an integer number of the desired length that is less than or equal to 32. For example, to create a 6-bit pattern, the user
can set the length to 18 (0001) or to 24 (0111) or to 30 (1101).
Length (Bits)
RPL3
RPL2
RPL1
RPL0
17
0
0
0
0
18
0
0
0
1
19
0
0
1
0
20
0
0
1
1
21
0
1
0
0
22
0
1
0
1
23
0
1
1
0
24
0
1
1
1
25
1
0
0
0
26
1
0
0
1
27
1
0
1
0
28
1
0
1
1
29
1
1
0
0
30
1
1
0
1
31
1
1
1
0
32
1
1
1
1
Bit 4/Single Bit Error Insert (SBE). A low-to-high transition will create a single bit error. Must be cleared and set again for a
subsequent bit error to be inserted.
Bits 5 to 7/Error Insert Bits 0 to 2 (EIB0 to EIB2). Will automatically insert bit errors at the prescribed rate into the
generated data pattern. Can be used for verifying error detection features.
EIB2
EIB1
EIB0
ERROR RATE INSERTED
0
0
0
No errors automatically inserted
0
0
1
10E-1
0
1
0
10E-2
0
1
1
10E-3
1
0
0
10E-4
1
0
1
10E-5
1
1
0
10E-6
1
1
1
10E-7