3 wire secure door control unit – Hikvision DS-K1T341BMWI-T Touchless Identity Authentication Terminal User Manual
Page 25
DS-K11T341BM(W)I-T Touchless Identity Authentication Terminal User Manual
UM DS-K1T341BM(W)I-T Touchless Identity Authentication Terminal 031221NA
25
Figure 15, Device Wiring
NOTE:
You should set the temperature screening terminal’s Wiegand direction as
Input
to connect
to a Wiegand card reader. If connects to an access controller, you should set the Wiegand
direction as
Output
to transmit authentication information to the access controller.
For details about Wiegand direction settings, see
The suggested external power supply for door lock is 12 V, 1 A. The suggested external
power supply for the Wiegand card reader is 12 V, 1A.
Do not wire the device to the electric supply directly.
If the interface for network connection is too large, you can use the supplied cable as shown
below.
Figure 16, Cable Diagram
4.3 Wire Secure Door Control Unit
You can connect the terminal with the secure door control unit.
The wiring diagram is as follows.