By default, Sector 13 is encrypted. It is recommended to encrypt sector 13.

6. Click

Save

to save the settings.

Set RS-485 Parameters

You can set the access control device’s RS-485 parameters including the baud rate, data bit, the stop bit, parity

type, flow control type, communication mode, work mode, and connection mode.

Before You Start

Add access control device to the client, and make sure the device supports RS-485 interface.

1. Enter the

Access Control

module.

2. On the navigation bar on the left, enter

Advanced Function

More Parameters

.

3. Select an access control device in the device list and click

RS-485

to enter the RS-485 Settings page.

4. Select the serial port number from the drop-down list to set the RS-485 parameters.

5. Set the baud rate, data bit, the stop bit, parity type, communication mode, working mode, and connection

mode in the drop-down list.

NOTE:

When the connection mode is

Connect Access Control Device

, you can select

Card No.

or

Person ID

as the output type.

6. Click

Save

.

The configured parameters will be applied to the device automatically.

When you change the working mode or connection mode, the device will reboot automatically.

Set Wiegand Parameters

You can set the access control device’s Wiegand channel and the communication mode. After setting the

Wiegand parameters, the device can connect to Wiegand card reader via Wiegand communication.

NOTE:

This function should be supported by the device.

1. Enter the

Access Control

module.

2. On the navigation bar on the left, enter

Advanced Function

More Parameters

.

3. Select an access control device in the device list and click

Wiegand

to enter the Wiegand Settings page.

4. Set the switch to on to enable the Wiegand function for the device.

5. Select the Wiegand channel No. and the communication mode from the drop-down list.

NOTE:

If you set Communication Direction as Sending, you are required to set the Wiegand Mode

as Wiegand 26 or Wiegand 34.

6. Check

Enable Wiegand