6.

Operation:

Mode

Flow

Chart

(11) Stop Mode: - It defines the power saving method on standby after completion of

positioning to the target position set in the “Position” field of the position

number.

0: Invalid power saving method * The default setting is 0 (invalid).

1: Auto servo OFF method. Delay time defined with the parameter No. 36

2: Auto servo OFF method. Delay time defined with the parameter No. 37

3: Auto servo OFF method. Delay time defined with the parameter No. 38

4: Full servo control method

Full servo control method

The holding current can be reduced by servo-controlling the pulse motor.

The degree of reduction varies depending on the actuator model, load condition, etc.,

but the holding current decreases approximately by a factor of 2 to 4.

No displacement occurs since this method maintains the servo ON status.

The actual holding current can be checked on the monitoring screen of PC-compatible

software.

Auto servo OFF method

When a given length of time has elapsed after completion of positioning, the servo OFF

status is automatically entered.

(Since the holding current does not flow, the power consumption can be saved by the

same amount.)

When a movement command is subsequently given fr om PLC, the status returns to

the servo ON and the actuator starts to move.

Movement
command

Servo status

Actuator
movement

Servo ON status

Auto servo OFF

(Green LED flashing)

Target position

T: Delay time (sec) until the servo

OFF status is entered after
completion of positioning
It is set with the parameter.