Selftest Failures

Memory Failures

The B1000/C3000 system requires Memory Page Deallocation to be implemented. This
feature allows the workstation to provide information to the operating system about
memory failures.

HP-UX 10.20 or later uses information to map out failing memory areas and continue
normal operation. You can use the command

memrpt

with the

detail

switch to obtain

information about the Memory Page Deallocation Table (PDT) as well as single-bit errors
logged by the system.

# /usr/sbin/sysdiag

Enter

DUI > logtool

Enter

LOGTOOL> memrpt detail

Enter

The PDT can also be checked using the

pdt

command in the Service menu of the Boot

Console Handler (refer to “Boot Console Menus” on page 159).

For allowable memory configurations see Chapter 2 of this manual.

INI

CC4n

SYS BD

CPU

n mem rendez

Slave CPU n entering memory
rendezvous, waiting for the monarch CPU
to select a boot device.

TST

D000

SYS BD

micro controller

Firmware is initializing communications
with the system controller.

WRN

D004

SYS BD

micro not resp

Firmware detected a communications
error with the system controller.

INI

D005

SYS BD

set dom1 fan spd

Firmware is initializing communications
with the system controller.

INI

D006

SYS BD

set dom2 fan spd

Firmware is initializing communications
with the system controller.

WRN

D007

SYS BD

bad microctl cmd

Firmware detected a communications
error with the system controller.

FLT

D01n

SYS/IO

fan n: failure!

Firmware detected system fan n stopped.

WRN

D02n

SYS/IO

fan n: too slow!

Firmware detected system fan n is
running too slowly.

Table 3-2. Chassis Codes for B1000/C3000 Workstations

Ostat

Code

FRU

Message

Description