Troubleshooting
Selftest Failures
Memory Failures
The B1000/C3000 system requires Memory Page Deallocation to be implemented. This
feature allows the workstation to provide information to the operating system about
memory failures.
HP-UX 10.20 or later uses information to map out failing memory areas and continue
normal operation. You can use the command
memrpt
with the
detail
switch to obtain
information about the Memory Page Deallocation Table (PDT) as well as single-bit errors
logged by the system.
# /usr/sbin/sysdiag
Enter
DUI > logtool
Enter
LOGTOOL> memrpt detail
Enter
The PDT can also be checked using the
pdt
command in the Service menu of the Boot
Console Handler (refer to “Boot Console Menus” on page 159).
For allowable memory configurations see Chapter 2 of this manual.
INI
CC4n
SYS BD
CPU
n mem rendez
Slave CPU n entering memory
rendezvous, waiting for the monarch CPU
to select a boot device.
TST
D000
SYS BD
micro controller
Firmware is initializing communications
with the system controller.
WRN
D004
SYS BD
micro not resp
Firmware detected a communications
error with the system controller.
INI
D005
SYS BD
set dom1 fan spd
Firmware is initializing communications
with the system controller.
INI
D006
SYS BD
set dom2 fan spd
Firmware is initializing communications
with the system controller.
WRN
D007
SYS BD
bad microctl cmd
Firmware detected a communications
error with the system controller.
FLT
D01n
SYS/IO
fan n: failure!
Firmware detected system fan n stopped.
WRN
D02n
SYS/IO
fan n: too slow!
Firmware detected system fan n is
running too slowly.
Table 3-2. Chassis Codes for B1000/C3000 Workstations
Ostat
Code
FRU
Message
Description