beautypg.com

Table row, 730c, Sys bd – HP B1000 User Manual

Page 71: Mem intrlv fail, Memory interleave generation failed, 730f, Mem config done, Main memory configuration complete, Dimm, Non-dest mem tst

background image

Chapter 3

71

Troubleshooting

Selftest Failures

FLT

730C

SYS BD

mem intrlv fail

Memory interleave generation failed.

INI

730F

SYS BD

mem config done

Main memory configuration complete.

TST

7400

DIMM

non-dest mem tst

Starting non-destructive memory test.

TST

740F

DIMM

non-dst tst done

Non-destructive memory test complete.

INI

7500

SYS BD

memory reset

Resetting memory system.

WRN

7501

SYS BD

mem log clr warn

Memory error logs didn’t clear on first try.

FLT

7502

SYS BD

mem err log fail

Firmware could not clear memory error
logs.

TST

7600

DIMM

dest mem test

Starting the destructive memory test.

WRN

7601

DIMM

mem init only

Skip the test, just initialize memory to
save time.

TST

7602

DIMM

tst 1st mem page

Starting 3-pass test of first memory page.

TST

7603

DIMM

tst rest of mem

Starting 3-pass test of the rest of memory.

TST

7604

DIMM

start 1st pass

Starting 1st pass of memory test (write
pseudorandom sequence).

TST

7605

DIMM

1st pass

x%

First pass is x% complete.

TST

7606

DIMM

start 2nd pass

Starting 2nd pass of memory test (verify
pseudorandom sequence, write inverse).

TST

7607

DIMM

2nd pass

x%

Second pass is x% complete.

TST

7608

DIMM

start 3rd pass

Starting 3rd pass of memory test (verify
inverse sequence).

TST

7609

DIMM

3rd pass x%

Third pass is x% complete.

TST

760A

DIMM

start mem init

Starting memory initialization. (Initialize
to zero to set ECC.)

TST

760B

DIMM

mem init

x%

Memory initialization is x% complete.

WRN

760C

DIMM

repeat dest test

Re-execute destructive test for hardware
troubleshooting.

FLT

760D

DIMM

mem code cpy err

Firmware tried to copy code from ROM to
memory, but the copy didn’t match the
original.

FLT

7610

DIMM

ECC wrt/read err

Writing and reading back good data
caused memory ECC error.

FLT

7611

DIMM

ECC single data

Memory ECC test failed to detect
single-bit data error.

Table 3-2. Chassis Codes for B1000/C3000 Workstations

Ostat