Table row, 1n13, Sys bd – HP B1000 User Manual
Page 62: Data mem brk trp, 1n14, Tlb dirty bit tr, Cpu n detected an unexpected tlb dirty bit trap, 1n15, 1n16, Assist emul trap

62
Chapter 3
Troubleshooting
Selftest Failures
FLT
1n13
SYS BD
data mem brk trp
CPU n detected an unexpected data
memory break trap.
FLT
1n14
SYS BD
TLB dirty bit tr
CPU n detected an unexpected TLB dirty
bit trap.
FLT
1n15
SYS BD
page refrnce trp
CPU n detected an unexpected page
reference trap.
FLT
1n16
SYS BD
assist emul trap
CPU n detected an unexpected assist
emulation trap.
FLT
1n17
SYS BD
hi-priv xfer trp
CPU n detected an unexpected
higher-privilege transfer trap.
FLT
1n18
SYS BD
lo-priv xfer trp
CPU n detected an unexpected
lower-privilege transfer trap.
FLT
1n19
SYS BD
taken branch trp
CPU n detected an unexpected
taken-branch trap.
FLT
1n1A
SYS BD
data mem acc rts
CPU n detected an unexpected data
memory access rights trap.
FLT
1n1B
SYS BD
data mem prot ID
CPU n detected an unexpected data
memory protection ID trap.
FLT
1n1C
SYS BD
unalign data ref
CPU n detected an unexpected unaligned
data reference trap.
FLT
1n1D
SYS BD
perf mon intrrpt
CPU n detected an unexpected
performance monitor interrupt.
TST
1n20
SYS BD
CPU
n basic test
CPU n is starting its basic operations
self-test.
TST
1n21
SYS BD
CPU
n alu test
CPU n is starting its arithmetic and
logical unit self-test.
TST
1n22
SYS BD
CPU
n branch test
CPU n is starting its branch instruction
self-test.
TST
1n23
SYS BD
CPU
n arith cond
CPU n is starting its arthimetic condition
self-test.
TST
1n24
SYS BD
CPU
n bit opers
CPU n is starting its bit operation
instruction self-test.
TST
1n25
SYS BD
CPU
n cntrl regs
CPU n is starting its control register
self-test.
TST
1n26
SYS BD
CPU
n ext intrpt
CPU n is starting its external interrupt
self-test.
Table 3-2. Chassis Codes for B1000/C3000 Workstations
Ostat
Code
FRU
Message
Description