Table row, Sys bd, Search for imm – HP B1000 User Manual
Page 69: 703s, Dimm, Dimm s imm vrfy, 704s, Dimm s imm fail, Dimm s failed the initial memory module test, 705s
![background image](/manuals/97383/69/background.png)
Chapter 3
69
Troubleshooting
Selftest Failures
TST
7020
SYS BD
search for IMM
Try to find a single memory bank to use
for the initial memory module.
TST
703s
DIMM
DIMM
s IMM vrfy
DIMM s was the initial memory module
last boot. Verify it still works.
FLT
704s
DIMM
DIMM
s
IMM fail
DIMM s failed the initial memory module
test.
TST
705s
DIMM
DIMM
s IMM test
Test DIMM in slot s as the initial memory
module.
INI
706s
DIMM
DIMM
s
is IMM
DIMM s chosen as initial memory module.
INI
70F0
DIMM
DIMM scan done
Memory DIMM scan complete.
TST
7100
SYS BD
mem register tst
Start testing registers in memory
controller.
WRN
7101
SYS BD
skip mem reg tst
Bypass the memory controller register
test.
FLT
7102
SYS BD
mem addr reg tst
Firmware detected an error in the
memory controller address registers.
FLT
7103
SYS BD
mem mbat reg tst
Firmware detected an error in the
memory controller bank registers.
FLT
7104
SYS BD
mem reg tst fail
Firmware detected an error in the
memory controller memory registers.
FLT
7105
SYS BD
mem err reg test
Firmware detected an error in the
memory controller error registers.
FLT
7106
SYS BD
mem err clr fail
Firmware was unable to clear the error
registers after testing.
INI
7200
DIMM
strt DIMM detect
Start the Serial Presence Detection (SPD)
to search for memory DIMMs.
INI
7201
DIMM
DIMM detect
x%
SPD is x% finished.
WRN
7202
SYS BD
skip DIMM detect
Bypass Serial Presence Detection.
FLT
7203
DIMM
unsupp DIMM type
SPD found an unsupported DIMM type.
FLT
7204
DIMM
SPD fatal error
SPD detected an unexpected, fatal error.
INI
7205
DIMM
add HP DIMM type
New HP manufactured DIMM type added
to tables.
INI
7206
DIMM
non-HP DIMM type
New non-HP DIMM type added to tables
(use at own risk).
Table 3-2. Chassis Codes for B1000/C3000 Workstations
Ostat
Code
FRU
Message
Description