Table row, Dimm, Dimm table full – HP B1000 User Manual
Page 70: The dimm table is full--cannot add new type, No dimms found, Spd didn’t find any memory dimms, 721s, Is dimm s inst, Is dimm, Spd is checking memory slot s
![background image](/manuals/97383/70/background.png)
70
Chapter 3
Troubleshooting
Selftest Failures
FLT
7207
DIMM
DIMM table full
The DIMM table is full--cannot add new
type.
FLT
7208
DIMM
no DIMMs found
SPD didn’t find any memory DIMMs.
INI
721s
DIMM
is DIMM
s inst?
SPD is checking memory slot s.
INI
722s
DIMM
???? DIMM in
s
SPD found a DIMM in slot s, but can’t
determine its size. DIMM will not be used.
INI
723s
DIMM
128M DIMM in
s
SPD found a 128MB DIMM in slot s.
INI
724s
DIMM
256M DIMM in
s
SPD found a 256MB DIMM in slot s.
INI
725s
DIMM
512M DIMM in
s
SPD found a 512MB DIMM in slot s.
FLT
72As
DIMM
DIMM
s checksum
DIMM in slot s failed SPD checksum and
will not be used.
FLT
72Cs
DIMM
DIMM
s mismatch
DIMM in slot s didn’t match the other in
pair. (J7000 only--DIMMs must be in
matched pairs.)
FLT
72D
s
DIMM
DIMM
s load err
Memory DIMMs are not in the proper
order. As a result, the system cannot
access DIMM s and has deallocated it.
INI
7300
SYS BD
mem config start
Starting main memory configuration.
TST
7301
SYS BD
check mem config
Checking for memory configuration
change since last boot.
WRN
7302
SYS BD
mem confg changd
Memory physical configuration changed
since last boot.
INI
7303
SYS BD
use saved config
Memory physical configuration didn’t
change. Use stored configuration data.
INI
7304
SYS BD
build mem intrlv
Building memory configuration with all
DIMMs interleaved.
INI
7305
SYS BD
save mem config
Saving memory configuration information
in non-volatile memory.
WRN
7306
SYS BD
use alt mem conf
Memory will be configured from fixed
values, instead of detected DIMMs.
INI
7307
SYS BD
interleve memory
Generating the memory interleave.
FLT
7308
SYS BD
PDT is disabled
Firmware detected bad memory pages,
but the Page Deallocation Table is
disabled.
FLT
7309
DIMM
insufficient mem
Insufficient error-free memory to
continue.
Table 3-2. Chassis Codes for B1000/C3000 Workstations
Ostat
Code
FRU
Message
Description