70

Chapter 3

Troubleshooting

Selftest Failures

FLT

7207

DIMM

DIMM table full

The DIMM table is full--cannot add new
type.

FLT

7208

DIMM

no DIMMs found

SPD didn’t find any memory DIMMs.

INI

721s

DIMM

is DIMM

s inst?

SPD is checking memory slot s.

INI

722s

DIMM

???? DIMM in

s

SPD found a DIMM in slot s, but can’t
determine its size. DIMM will not be used.

INI

723s

DIMM

128M DIMM in

s

SPD found a 128MB DIMM in slot s.

INI

724s

DIMM

256M DIMM in

s

SPD found a 256MB DIMM in slot s.

INI

725s

DIMM

512M DIMM in

s

SPD found a 512MB DIMM in slot s.

FLT

72As

DIMM

DIMM

s checksum

DIMM in slot s failed SPD checksum and
will not be used.

FLT

72Cs

DIMM

DIMM

s mismatch

DIMM in slot s didn’t match the other in
pair. (J7000 only--DIMMs must be in
matched pairs.)

FLT

72D

s

DIMM

DIMM

s load err

Memory DIMMs are not in the proper
order. As a result, the system cannot
access DIMM s and has deallocated it.

INI

7300

SYS BD

mem config start

Starting main memory configuration.

TST

7301

SYS BD

check mem config

Checking for memory configuration
change since last boot.

WRN

7302

SYS BD

mem confg changd

Memory physical configuration changed
since last boot.

INI

7303

SYS BD

use saved config

Memory physical configuration didn’t
change. Use stored configuration data.

INI

7304

SYS BD

build mem intrlv

Building memory configuration with all
DIMMs interleaved.

INI

7305

SYS BD

save mem config

Saving memory configuration information
in non-volatile memory.

WRN

7306

SYS BD

use alt mem conf

Memory will be configured from fixed
values, instead of detected DIMMs.

INI

7307

SYS BD

interleve memory

Generating the memory interleave.

FLT

7308

SYS BD

PDT is disabled

Firmware detected bad memory pages,
but the Page Deallocation Table is
disabled.

FLT

7309

DIMM

insufficient mem

Insufficient error-free memory to
continue.

Table 3-2. Chassis Codes for B1000/C3000 Workstations