Table row, 1nba, Sys bd – HP B1000 User Manual
Page 64: Monarch cpu fail, Monarch cpu, The monarch cpu failed, 1nbb, Bad cpun number, Bad cpu, The cpu identifier was out of range

64
Chapter 3
Troubleshooting
Selftest Failures
FLT
1nBA
SYS BD
monarch CPU
fail
The monarch CPU failed.
FLT
1nBB
SYS BD
bad CPU
n number
The CPU identifier was out of range.
FLT
1nBF
SYS BD
CPU
n halt boot
Bootstrap failure--machine halted.
INI
1nCA
SYS BD
CPUn sys bus arb
Monarch CPU is initializing the system
bus arbitration.
WRN
1nCD
SYS BD
CPU
n deconfig
CPU n deconfigured itself.
WRN
1nCE
SYS BD
CPU
n extinguish
PDC_PROC halted CPU n.
FLT
1nCF
SYS BD
slave
n failed
Slave CPU n failed self-test.
WRN
1mDs
SYS BD
slaves deconfig
Monarch CPU m deconfigured slave CPU
s.
WRN
1nEF
SYS BD
CPU
n slftst warn
CPU n detected a non-fatal error during
its self-tests.
WRN
1mFs
SYS BD
mon
m stop slaves
Monarch CPU m halted slave CPU s.
INI
1nFC
SYS BD
CPUn sync’ing
CPU n is synchronizing with the rest of
the system.
INI
1nFD
SYS BD
CPU
n stat wd tst
CPU n is testing the system status word.
FLT
1nFF
SYS BD
monarch
n selftst
Monarch CPU n failed self-test.
TST
2n20
SYS BD
CPU
n icache RAM
CPU n is starting its instruction cache
RAM self-test.
FLT
2n25
SYS BD
CPU
n ic ld d err
CPU n detected a data error during data
cache load.
FLT
2n26
SYS BD
CPU
n ic ld t err
CPU n detected a tag error during data
cache load.
TST
2n30
SYS BD
CPU
n icache tag
CPU n is starting its instruction cache tag
self-test.
TST
2n40
SYS BD
CPU
n icache par
CPU n is starting its instruction cache
parity detection self-test.
TST
2n50
SYS BD
CPU
n dc stor que
CPU n is starting its data cache store
queue self-test.
FLT
2n51
SYS BD
CPU
n dc st q err
CPU n detected an error during its data
cache store queue self-test.
TST
2n70
SYS BD
CPU
n dcache RAM
CPU n is starting its data cache RAM
self-test.
TST
2n80
SYS BD
CPU
n dcache tag
CPU n is starting its data cache tag
self-test.
Table 3-2. Chassis Codes for B1000/C3000 Workstations
Ostat
Code
FRU
Message
Description