Table row, 4n60, Sys bd – HP B1000 User Manual

Page 68: Cpun dcache miss, Cpu n is starting its data cache miss self-test, 5n00, Unknown bus err, 5n02, Path err assertd, 5n04

background image

68

Chapter 3

Troubleshooting

Selftest Failures

TST

4n60

SYS BD

CPU

n dcache miss

CPU n is starting its data cache miss
self-test.

FLT

5n00

SYS BD

unknown bus err

CPU n detected an unknown error on the
system bus (Runway).

FLT

5n02

SYS BD

path err assertd

CPU n detected a path error on the
system bus (Runway).

FLT

5n04

SYS BD

data parity err

CPU n detected a data, address, or control
parity error on the system bus (Runway).

FLT

5n07

SYS BD

Runway dir error

CPU n detected a directed error on the
system bus (Runway).

FLT

5n08

SYS BD

Runway broad err

CPU n detected a broadcast error on the
system bus (Runway).

FLT

5n0A

SYS BD

illegal response

CPU n received data that did not match
any outstanding data request.

FLT

5n0B

SYS BD

bus timeout

CPU n timed out before receiving
requested data. The responder is logged in
the system responder address.

FLT

5n0C

SYS BD

CPU sync failure

CPU n’s synchronizer detected a rule
violation on the system bus (Runway).

INI

7000

DIMM

start DIMM scan

Start looking for installed DIMMs.

INI

7002

SYS BD

init mem tables

Initialize memory data structures.

FLT

7004

SYS BD

mem plt upd fail

Error updating memory platform data.

FLT

7005

DIMM

insufficient mem

Insufficient memory detected to continue.

TST

7010

DIMM

check DIMM order

Start memory DIMM order check.

WRN

7011

DIMM

skip DIMM ord ck

Bypass memory DIMM order check.

FLT

7012

DIMM

DIMM order error

Memory DIMMs are not in the proper
order.

FLT

7013

DIMM

DIMM order error

Memory DIMMs are not in the proper
order. As a result, the system cannot
access one or more DIMMs and has
deallocated all inaccessible DIMMs.

TST

7016

DIMM

DIMM pair check

Start memory DIMM pair check (DIMMs
in a pair (e.g. 0a/0b) must match in
J7000).

WRN

7017

DIMM

skip mem pair ck

Bypass memory DIMM set check.

FLT

701F

DIMM

no memory found

Memory scan couldn’t find any DIMMs.

Table 3-2. Chassis Codes for B1000/C3000 Workstations