A
Summary of Commands
detach
UCS 1000 R4.2 Administration 585-313-507
Issue 3 April 2000 424
•
-n
— This optional parameter disables prompting from the system
whether to wait until a conflict has been resolved (see the
-i
option below)
or to terminate the request to detach.
•
-i
— This optional parameter is used to enable secondary command
registration. If T1 diagnostics are being run, this option allows the
“detaching” of another card. If
-i
is used and another maintenance
command is being run (
remove
,
detach
,
attach
,
restore
,
diagnose), the
request to detach
is blocked and a message is printed to the screen. If
-i
is not used and any maintenance command is being run, the request to
detach is blocked and a message is printed to the screen.
If the command is permitted to run, a check is made to see if the
command is in conflict with another. A command is in conflict if the card or
card associated with it:
~
Is the T1 card being diagnosed
~
Will cause a change in the existing TDM bus master assignment
~
Has an interdependency with the T1 card being diagnosed (for
example, PRI)
If one of the above conflicts exist and
-n
is not used, the user is asked
whether to wait until the conflict is resolved or to terminate the request. If
T1 diagnostics are executing online tests and a conflict is detected, the
detach
command is blocked. If T1 diagnostics are executing offline tests
and a conflict is detected, the user is asked whether to wait until the
conflict is resolved or to terminate the request to detach.