beautypg.com

8032 enclosure power removed, 8033 enclosure power added, 8034 enclosure power unknown – Avago Technologies 3ware 9650SE-12ML (Channel) User Manual

Page 320

background image

Troubleshooting

308

3ware SAS/SATA RAID Software User Guide, Version 9.5.1

Action

Reseat the power supply cord. Replace any failed power supply as soon as
possible.

It is recommended to use an uninterruptible power supply (UPS) to protect
against power failures.

8032 Enclosure power removed

Event Type

Warning.

Cause

Applies only to the 9690SA controller.

One of the enclosure power supplies has been removed from the enclosure or
a power supply is unplugged.

Action

Return or reconnect the power supply as soon as possible.

It is recommended to use an uninterruptible power supply (UPS) to protect
against power failures.

8033 Enclosure power added

Event Type

Information.

Cause

Applies only to the 9690SA controller.

A power supply has been added to the enclosure or an existing power supply
has been plugged in.

Action

None required.

8034 Enclosure power unknown

Event Type

Warning.