002d source drive error occurred, 002e replacement drive capacity too small – Avago Technologies 3ware 9650SE-12ML (Channel) User Manual
Page 292

Troubleshooting
280
3ware SAS/SATA RAID Software User Guide, Version 9.5.1
002D Source drive error occurred
Event Type
Error
Cause
An error on the source drive was detected during a rebuild operation. The
rebuild has stopped as a result.
Action
The controller will report an error, even if the area of the source drive that had
the error did not contain data. Scheduling regular verifies will lessen the
chance of getting this error.
You can force the rebuild to continue by setting the Overwrite ECC Error
policy through 3DM, CLI, or 3BM, and then rebuilding the unit again. This
will cause uncorrectable blocks to be rewritten, but the data may be incorrect.
It is recommended that you execute a file system check when the rebuild
completes.
Under Windows, right-click on your drive icon and choose
Properties>
Tools> Check Now
.
Under Linux or FreeBSD use
fsck /dev/sda1
. If you have more than one
SATA device, substitute the correct drive letter and partition number, such as
sdb2, for sda1.
See Also
“Starting a Verify Manually” on page 165
“Enabling or Disabling Auto Verify for a Unit” on page 120
“Setting Overwrite ECC (Continue on Source Error When Rebuilding)” on
page 121
002E Replacement drive capacity too small
Event Type
Error
Cause
The storage capacity of the drive you are using as a replacement drive is too
small and cannot be used.