beautypg.com

000b rebuild started, 000c initialize started – Avago Technologies 3ware 9650SE-12ML (Channel) User Manual

Page 281

background image

Error and Notification Messages

www.3ware.com

269

Action

If you see this message, the drive repairs may lie outside of the 3ware RAID
controller’s abilities.Try running the drive manufacturer’s diagnostic and
repair utilities on the drive.

If necessary, replace the drive.

See Also

For links to drive manufacturer diagnostic utilities and troubleshooting
advice, see

http://www.3ware.com/KB/article.aspx?id=10894

.

000B Rebuild started

Event Type

Information

Cause

The 3ware RAID controller started to rebuild a degraded unit. The rebuild
may have been initiated by you, may have started automatically on a hot spare
or may have started after drive removal or insertion (due to the Auto Rebuild
policy).

Action

Allow the rebuild to complete. This will return the unit to its normal
redundant state.

See Also

“Scheduling Background Tasks” on page 173
“Rebuilding Units” on page 167
“Background Task Prioritization” on page 173

000C Initialize started

Event Type

Information

Cause

The 3ware RAID controller started an initialization. This is always a
“synching” background initialization and does not erase user data.
Initialization either occurs at unit creation time for larger RAID 5, 6, or 50
units or later during the initial verification of redundant units.