Avago Technologies 3ware 9650SE-12ML (Channel) User Manual
Page 118

Configuring Units
106
3ware SAS/SATA RAID Software User Guide, Version 9.5.1
Figure 46. Configuring a Unit in 3DM
4
In the
Type
field, select the RAID configuration you want.
5
If stripe size applies to the RAID type you select, select a
Stripe Size
.
(Stripe size does not apply to RAID 1.)
6
Optional: In the
Name
box, enter a name for the unit (up to 21 characters,
including dashes and underscores).
7
If you have 12 drives attached to the controller and selected RAID 50 as
the configuration in step 3, select whether you want 3, 4, or 6 Drives Per
Subunit, as shown here.
Figure 47. Configuring a RAID 50 with 12 Drives
8
Make changes to the unit policies, as desired. You can enable or disable
the
Write Cache
,
Auto Verify
, and
Overwrite ECC
. You can also set the
StorSave
policy and
Rapid RAID Recovery
policy.
For details about these settings, see “Setting Unit Policies” on page 116.