Avago Technologies 3ware 9650SE-12ML (Channel) User Manual
Page 178

Maintaining Units
166
3ware SAS/SATA RAID Software User Guide, Version 9.5.1
To verify a unit through 3DM
1
In 3DM, choose
Management > Maintenance
.
2
In the
Unit Maintenance
section of the Maintenance page, select the unit
you want to verify and click
Verify Unit
.
3DM puts the selected unit in verifying mode.
If Basic Verify is selected on the Scheduling page, the verification process
begins almost immediately. If Advanced Verify is selected, the unit will
not start actively verifying until the next scheduled time.
A
Stop Verify
link appears next to the unit on the Maintenance page. If
you need to stop the verify process, use this link. (If initialization starts
because the unit had not previously been initialized, it cannot be halted, so
no
Stop Verify
link appears.)
To verify a unit through 3BM
1
At the main 3BM screen, select the unit by highlighting it and pressing
Enter.
An asterisk appears in the left-most column to indicate that it is selected.
2
Tab
to the
Maintain Unit
button and press
Enter
.
3
On the pop-up menu, select
Verify
and press
Enter
.
Verification of the selected unit starts immediately.
Figure 66. Verifying a Unit