beautypg.com

Avago Technologies 3ware 9650SE-12ML (Channel) User Manual

Page 106

background image

Configuring Your Controller

94

3ware SAS/SATA RAID Software User Guide, Version 9.5.1

Figure 40. Auto-Carve policy in 3BM

2

Create a new unit or migrate an existing unit to include the drives you
want to use.

If the combined capacity of the drives exceeds the carve size, a number of
volumes will be created.

3

Verify the creation of the volumes.

In 3DM 2, the number of volumes is shown on the Unit Details page.

4

Verify that the volumes appear in the operating system. They will appear
as additional drives.

Notes:

If you are configuring a unit for primary storage and it will be greater than 2 TB,
be sure to enable the auto-carve policy before creating the unit.

When volumes have been created through auto-carving, they cannot be
deleted except by deleting the unit.

If you create a bootable unit that has multiple volumes, the first volume can be
used as the boot device.

Changing the auto-carve policy does not affect existing units.