0052 Battery health check completed

Event Type

Information

Cause

The Battery Backup Unit evaluates periodically the health of the battery and
its ability to backup the 3ware RAID controller in case of a power failure.
This message is posted to the host when this health check has completed.

0053 Battery capacity test is overdue

Event Type

Information

Cause

There has not been a battery capacity test run in the last 6 months, which is the
maximum recommended interval. This message will be sent once every week
until the test is run.

Action

AMCC recommends running the test at least once every 6 months, if the
measured battery capacity is longer than 120 hours. If the measured battery
capacity is less than 120 hours the recommended test interval is 4 weeks.

0055 Battery charging started

Event Type

Information

Cause

The Battery Backup Unit has started a battery charge cycle.

Action

None required