Error and Notification Messages

www.3ware.com

285

Cause

The 3ware 9500S RAID controller is inoperable due to missing SO-DIMM
memory.

Note:

This message only applies to the 3ware 9500S controller, which has

removable memory. Other 3ware controller models do not have memory that
can be removed.

Action

Install a compatible SO-DIMM on the controller.

See Also

For a list of SODIMMs compatible with the 9500S, see

http://www.3ware.com/KB/article.aspx?id=11748

.

0039 Buffer ECC error corrected

Event Type

Warning

Cause

The controller has detected and corrected a memory ECC error.

Action

None required.

If errors persist, contact technical support at

http://www.3ware.com/support/

index.asp.

003A Drive power on reset detected

Event Type

Error

Cause

The controller has detected that a drive has lost power and then restarted. The
controller may degrade the unit if it is a redundant unit (non-redundant units
cannot be degraded).