Troubleshooting

270

3ware SAS/SATA RAID Software User Guide, Version 9.5.1

Action

Allow the initialization to complete. This will return the unit to its normal
redundant state.

See Also

For more information, see “About Initialization” on page 158

000E Initialize failed

Event Type

Error

Cause

The 3ware RAID controller was unable to complete the initialization. This
error can be caused by unrecoverable drive errors.

If this unit was a redundant unit, and the initialization failed because of a
problem on a particular disk drive, then the unit will be degraded.

Action

If the unit was degraded, then rebuild the unit. This may necessitate replacing
the drive.

Check physical cable and power connections. You can also run the drive
manufacturer’s diagnostic and repair utilities on the drive.

See Also

For links to drive manufacturer diagnostic utilities and troubleshooting
advice, see

http://www.3ware.com/KB/article.aspx?id=10894

.

“Basic Troubleshooting: Check This First” on page 251

000F SMART threshold exceeded

Event Type

Warning

Cause

SMART monitoring is predicting a potential drive failure.

The 3ware RAID controller supports SMART monitoring, whereby the
individual drives automatically monitor certain parametric information such