002f verify not started; unit never initialized, 0030 drive not supported – Avago Technologies 3ware 9650SE-12ML (Channel) User Manual

Page 293

background image

Error and Notification Messages

www.3ware.com

281

Action

Use a replacement drive equal to or larger than the drives already in use

002F Verify not started; unit never initialized

Event Type

Warning

Cause

A verify operation has been attempted by the 3ware RAID controller, but the
unit has never been initialized before. The unit will automatically transition to
initializing mode and then start a verify.

Action

None required.

This is considered a normal part of operation. Not all types of RAID units
need to be initialized in order to have full performance. The initialize will not
erase user data, but will calculate and write parity data or mirror data to the
drives in the unit.

See Also

“About Initialization” on page 158

0030 Drive not supported

Event Type

Error

Cause

3ware 8000 and 9500S Serial ATA controllers only support UltraDMA-100/
133 drives when using the parallel-to-serial ATA converter. This message
indicates that an unsupported drive was detected during rollcall or a hot swap.
This message could also indicate that the parallel-to-serial converter was
jumpered incorrectly.

Action

Use a parallel ATA drive which supports UDMA 100 or 133 and check that
the parallel-to-serial converter was correctly jumpered to correspond to
UDMA 100 or 133 drives.