Troubleshooting

272

3ware SAS/SATA RAID Software User Guide, Version 9.5.1

Action

The drive is now available for use. If the drive is part of a unit add the
remaining drives and rescan the controller, in 3DM or CLI, to bring the unit
online.

001E Unit inoperable

Event Type

Error

Cause

The 3ware RAID controller is unable to detect sufficient drives for the unit to
be operable. Some drives have failed or are missing.

Examples of inoperable units are as follows:

RAID 0 missing any drives.

A RAID 5 or 50 unit with two or more drives missing from the same
RAID 5 unit or subunits.

A RAID 10 unit with both drives missing from one of the RAID 1
subunits.

A RAID 6 unit with three or more drives missing.

Note:

The controller only generates this message if the unit is missing drives

for more than 20 seconds. This allows a hot swap of a drive to be completed
without generating this error.

Action

The unit is no longer available for use. Return all missing drives to the unit. If
the drives are physically present, check all data and power connections.

CAUTION:

Do not delete the inoperable unit and recreate it as this will

overwrite the data and make data recovery very difficult.

You may wish to contact technical support at

http://www.3ware.com/support

.

See Also

“About Inoperable Units” on page 152

001F Unit Operational

Event Type

Information