beautypg.com

005f cache synchronization failed; some data lost, 0062 enclosure removed, 0063 enclosure added – Avago Technologies 3ware 9650SE-12ML (Channel) User Manual

Page 312

background image

Troubleshooting

300

3ware SAS/SATA RAID Software User Guide, Version 9.5.1

You will also see this message if drive insertion causes a unit to become
operational and retained write cache data was flushed.

005F Cache synchronization failed; some data lost

Event Type

Error

Cause

The 3ware RAID controller performs cache synchronization when system
power is restored following a power failure. The cache synchronization was
not successful for some reason.

0062 Enclosure removed

Event Type

Warning.

Cause

Applies only to the 9690SA controller.

An enclosure is no longer accessible to the 9690SA RAID controller. The
likely cause is that the enclosure has been powered down or that a cable has
been unplugged.

0063 Enclosure added

Event Type

Information.

Cause

Applies only to the 9690SA controller.

An enclosure is now accessible to the 9690SA RAID controller. The likely
cause is that an enclosure connected to the controller has been powered up or
that a cable has been plugged in.