beautypg.com

Miscellaneous diagnostics, Printer adapter test, C-23 c-23 – Epson Equity 286 PLUS User Manual

Page 217

background image

You may see the following message if you attempt to run the

Change line test on a drive that does not support a change line,

such as a 360KB or 720KB drive:

Change line not available

The controller displays one of these messages when an error
occurs during a diagnostics procedure:

Bad address mark
Bad CRC error
Bad DMA error
Bad seek error
Diskette write protected
Media change error
Record not found
Timeout error

These errors could occur because of a faulty drive, controller, or
cable, or if you attempt to run a test on a write-protected or
unformatted diskette.

Miscellaneous Diagnostics

These tests are listed in the Miscellaneous diagnostics submenu

to

provide a complete check of the parallel and serial ports:

Printer adapter test
Comm. adapter test

Printer Adapter Test

This test checks the parallel port and the printer by sending a
pattern to the printer. If the printer does not print the pattern,

the test has failed.

Performing System Diagnostics

C-23