KACO Powador XP500-XP550-HV TL User Manual
Page 75
Operating Instructions Powador XP500/550-HV-TL
Page 75
Parameters
Parameters
Min
Max
Unit
Parameters
FRT Asynchronous
Level
0
100
V
The voltage level in order to separate Asynchro-
nous and synchronous. Inverter will recognize as
Asynchronous if the difference between inverter
sensing output voltage and RMS value of positive
value is less then this parameter level
COSPHI (P/Pn) Ramp
Time
0
99999
sec
The slope setup value for PF’s answering time in
Cosφ(P/Pn)
COSPHI_1
-1
1
-
The variable power factor reference according to
active power P_1
P1
0
100
%
The active power setup conference for COSPHI_1
COSPHI_2
-1
1
-
The variable power factor reference according to
active power P_2
P2
0
100
%
The active power setup conference for COSPHI_2
COSPHI_3
-1
1
-
The variable power factor reference according to
active power P_3
P3
0
100
%
The active power setup conference for COSPHI_3
COSPHI_4
-1
1
-
The variable power factor reference according to
active power P_4
P4
0
100
%
The active power setup conference for COSPHI_4
COSPHI_5
-1
1
-
The variable power factor reference according to
active power P_5
P5
0
100
%
The active power setup conference for COSPHI_5
COSPHI_6
-1
1
-
The variable power factor reference according to
active power P_6
P6
0
100
%
The active power setup conference for COSPHI_6
COSPHI_7
-1
1
-
The variable power factor Reference according to
active power P_7
P7
0
100
%
The active power setup conference for COSPHI_7
COSPHI_8
-1
1
-
The variable power factor reference according to
active power P_8
P8
0
100
%
The active power setup conference for COSPHI_8
COSPHI_9
-1
1
-
The variable power factor reference according to
active power P_9
P9
0
100
%
The active power setup conference for COSPHI_9
COSPHI_10
-1
1
-
The variable power factor Reference according to
active power P_10
P10
0
100
%
The active power setup conference for COSPHI_10
Table 19: Controller Parameters