beautypg.com

KACO Powador XP500-XP550-HV TL User Manual

Page 51

background image

Operating Instructions Powador XP500/550-HV-TL

Page 51

Faults and Warnings

Code Message

Warning Description

Possible problem and Solution(s)

11

Inv. Under Voltage

Inverter side Voltage under the
parameter [Grid Under Voltage
Level 2]

Possible problem
• The inverter voltage is too low
Solution(s)
• Check the inverter voltage
• Check the inverter parameter
• Check the MC21

12

Inv. Over Frequency

Inverter side Frequency over the
parameter [Grid over Frequency
Level 2]

Possible problem
• The grid frequency is outside the
permitted range
Solution(s)
• Check the grid frequency

13

Inv. Under Frequency Inverter side Frequency under

the parameter [Grid under
Frequency Level 2]

Possible problem
• The grid frequency is outside the
permitted range
Solution(s)
• Check the grid frequency

14

Inv. Over Current

Inverter side Current over the
parameter [Inverter OverCurrent
Level]

Possible problem
• Short circuit in the IGBT
• Short circuit in the Grid
Solution(s)
• Check the grid connection
• Check the inverter connection

15

MC21(Inv. MC) Failure Inverter side contactor(MC21)

failure

Possible problem
• MC21 contactor is open
• Auxiliary switch is inoperable
Solution(s)
• Check the wiring connection
• Change the MC21

16

Inv. Phase Order

Phase order failure on the
inverter side

Possible problem
• Phase order failure on the inverter
• Wrong phase rotation
Solution(s)
• Check the wiring connection
• Reverse two phases

18

Inductor or TR Over
Temp

Inductor or Transformer temper-
ature over 150°C

Possible problem
• Cabinet fan failure
Solution(s)
• Cleaning the filters
• Change the cabinet Fan

Table 10: Fault