beautypg.com

10 mmi submenus, 1 pv array, 2 string monitoring – KACO Powador XP500-XP550-HV TL User Manual

Page 35: Buttons, Storage/installation/start-up, Display meaning

background image

Operating Instructions Powador XP500/550-HV-TL

Page 35

Storage/Installation/Start-up

5.10 MMI submenus

5.10.1 PV Array

String monitoring is activated

PV Array

Strings

0.0

0.0

0.0

Power (kW)

Voltage (V)

Current (A)

Cell Temp. (°C)

N/A

N/A

N/A

Return to next higher level

Isolation R (kΩ)

0.0

Irr. (W/m

2

) Ambi.Temp. (°C) Wind (m/s)

N/A

Buttons

Display

Meaning

Measured
values

Current measured values for
the PV Array

Strings

String monitoring is activated

Figure 21: “PV Array” screen

5.10.2 String monitoring

Changes to the configuration for the current sensors first become effective after five minutes.

30

25

20

Page :

15

10

5

0

0

2.4

4.8

7.2

9.6

12

Yellow bars:
Average current values,
faulty channel

Magenta dots:
Actual current
values

Green bars:
Average current values,
functioning channel

Light blue line:
Average of all channels

Strings

Return to the

previous level

Current
actual values

Only current actual values
are displayed during the
first five minutes after the
function has been acti-
vated.

Average current
values of the
channels

The actual values for the
last five minutes are
recorded (sampling period:
every 30 seconds)

Average of all
current values
(channels)

Average of all current
values (channels)

Figure 22: “String monitoring” screen

If the average of one channel deviates from the average of all channels by more than the specified range of

tolerance and if this persists for longer than a specified delay period, this channel is assumed to be defective.