Operating Instructions Powador XP500/550-HV-TL
Faults and Warnings
Code Message
Warning Description
Possible problem and Solution(s)
41
Flash Memory
Failure
C6000 DSP program flash
memory failure in XCU(main
control) board
Possible problem
• Internal C6000 error
Solution(s)
• Change the PCB module
42
FPGA Failure
FPGA failure in XCU(main
control) board
Possible problem
• Internal FPGA error
Solution(s)
• Change the PCB module
43
DSP28x Failure
F2000 DSP failure in XCU(main
control) board
Possible problem
• Internal F2000 error
Solution(s)
• Change the PCB module
44
ADC Failure
ADC block failure in XCU(main
control) board
Possible problem
• Internal Analog to Digital converter
error
Solution(s)
• Change the PCB module
45
NVSRAM Failure
NVSRAM failure in XCU(main
control) board or invalid param-
eter
Possible problem
• Internal NVSRAM error
• Invalid parameter
Solution(s)
• Initialize the parameter menu setting in
the GUI
• Change the PCB module
47
CAN Failure
CAN bus communication failure Possible problem
• CAN bus communication Failure
Solution(s)
• Check the CAN bus Connection
• Check the CAN bus terminal registers
50
Emergency Stop
The door is open
Possible problem
• Front door is open
• Broken or out of alignment door switch
Solution(s)
• Close the door
• Align or replace door switch
Table 10: Fault