beautypg.com

KACO Powador XP500-XP550-HV TL User Manual

Page 49

background image

Operating Instructions Powador XP500/550-HV-TL

Page 49

Faults and Warnings

Code Message

Warning description

Possible problem and Solution(s)

130

Cabinet Over Temp.
Warning

The temperature of the cabinet
over the parameter [Cabinet
Temperature Maximum]

Possible problem
• Cabinet Fan Failure
Solution(s)
• Clean the air filters
• Change the cabinet fan

131

Cabinet Under Temp.
Warning

The temperature of the cabinet
falls below operational param-
eters [Cabinet Temperature
Minimum]

Possible problem
• Ambient temperature is too low for
operation

134

SMPS Warning

Failure of the control SMPS

Possible problem
• Failure of the control SMPS
Solution(s)
• Change the control SMPS

135

CAN TX Failure

CAN bus communication
transmission failure

Possible problem
• CAN bus communication Failure
Solution(s)
• Check the CAN bus Connection
• Check the CAN bus terminal registers

136

CAN RX Failure

CAN bus communication
reception failure

137

CAN EP Failure

CAN bus communication
Error-Passive error

138

CAN Bus-Off

CAN bus communication
Bus-off error

139

CAN Wrong Message Reception of Wrong message in

CAN bus communication

140

CAN Time Out

Time out in CAN bus communi-
cation

141

CAN Multiple Master There are multiple Masters in

CAN bus communication

Possible problem
• CAN ID is duplicated
Solution(s)
• Change the parameters in the GUI

Table 9: Warning

Fault

Code Message

Warning Description

Possible problem and Solution(s)

1

PV Over Voltage

PV voltage exceeds the param-
eter [DC over voltage Level]

Possible problem
• The voltage of the solar generator is too
high
Solution(s)
• Check the input voltage
• Check module wiring and system

Table 10: Fault