proLOG Installation

1. Find a convenient, easily accessible location

indoors within close proximity to an active
Ethernet port.

2. Run a cat 5 wire from the inverter to the

proLOG.

3. Connect the cat 5 cable to the RS 485

ports A and B at the inverter and proLOG
as shown.

4. Set the inverter to RS 485 by pressing both

display keys located directly under the LCD
display on the inverter door until the time
set menu option is displayed.

5. Press the left display key and scroll through

the menu options until the interface sub
menu is reached and change the setting to
RS485 by pressing the right key once.

6. Press both keys again to leave the settings

menu.

KACO proLOG quick start

5

2

CAUTION!
HAZARDOUS VOLTAGE

Before opening disconnect the
PV generator and the grid.

Note the order of the electrical connection.
1. Disconnect and verify AC and DC
wiring is not energized
2. GND
3. N
4. L1 and L2
5. Interfaces
6. Return
7. Hot

Disconnect in reverse order

ON ON

1 2

3