6 - 60

YASNAC PCNC PLC Programming Manual Chapter 6: PLC Instructions

(c) Control conditions

Designation of check data address (APSHXXXX)

Designate the address where the data to be checked are stored.

Parity check is made for 1 byte (8 bits) of data.

Designation of parity scheme (OE)

OE = 0:

Even parity check

OE = 1:

Odd parity check

Reset (RST)

RST = 0: Error output R1 is not reset.

RST = 1: Error output R1 is reset.

Execution command (ACT)

ACT = 0: The PARI instruction is not executed. R1 remains unchanged.

ACT = 1: The PARI instruction is executed.

Error output (R1)

If the result of parity check does not meet the designated parity scheme, “1”
is set for “R1” (R1 = 1).

(8) SUBP 014 (DATA CONVERT) RR after operation:

Ù

(a) Function

The instruction converts the binary data to the BCD data and the BCD data to
the binary data.

(b) Example