Yaskawa YASNAC PC NC PLC Programming Manual User Manual
Page 186

8 - 38
YASNAC PCNC PLC Programming Manual Chapter 8: Online Editing
8.8 List of Messages
Messages displayed during on-line editing are given in Tables 8.8, 8.9 and 8.10
8.8.1
List of Messages
Table 8.8.1.1 List of Messages
8.8.2
List of Warning Messages
Table 8.8.2.1 List of Warning Messages
Message
Description
COLLECTING
The nets are being selected.
DELETING
The net is being deleted.
DELETION COMPLETED
Net deletion has been completed.
NET CHECKING
Entire sequence program is being checked during the execution of a sequence
program.
INPUTTING
Sequence program data are being input from a PC card.
INPUT COMPLETED
Inputting of sequence program data has been completed correctly.
OUTPUTTING
Sequence program data are being output to a PC card.
OUTPUT COMPLETED
Outputting of sequence program data has been completed correctly.
SEARCHING
Search processing is being executed on the ladder screen.
INPUT CONTACT NUMBER
The message requesting the input of a contact number when the contact function is
selected.
OVERWRITE? (Y/N)
When outputting a file to a PC card, the same file name as the one already existing in
the PC card is designated.
INITIALIZE SEQ.? (Y/N)
This message is displayed when the [
INITI
] function
soft-key
is pressed.
Message
Description
SELECTION OVER!
In net selection, more than 10 nets are selected.
INPUT ERROR!
Error in data input
CONTACT OVER!
More than 100 contacts are set in one net.
DEVICE NOT READY!
PC card is not set.
FORMAT ERROR!
PC card is not formatted.
ACCESS ERROR!
PC card read/write error.
PC CARD FULL!
PC card free area is insufficient for writing the data.
NO JMP-ADR!
ADR instruction is not designated corresponding to JMP.