beautypg.com

Yaskawa YASNAC PC NC PLC Programming Manual User Manual

Page 17

background image

3 - 4

YASNAC PCNC PLC Programming Manual Chapter 3: PLC Program Specifications

3.3 Input/Output Specifications

General-purpose input/output ports are installed on the I/O unit (Model: JANCD-FC810/FC860/
FC861) and the JSP board (JSP02/04).

The number of I/O points on each module is indicated below.

Table 3.4 Input/Output Specifications

An input/output port is incorporated control board (JSP02) in the NC operation panel.
Therefore, if modules FC810/FC860 are added, addition of a maximum of 4 boards
(max. input: 512 points; max. output: 440 points) is possible, and if module FC861 is
added, addition of a maximum of 9 boards (max. input: 640 points, max input: 560 points)
is possible.

Module Type JANCD-

Number of Input Points

Number of Output Points

Remark

FC810, FC860

112

96

For machine side inputs

FC861

64

56

JSP02

64

56