6 - 76

YASNAC PCNC PLC Programming Manual Chapter 6: PLC Instructions

Designation of the conversion type (STR#XXXX.X)

STR = 0: Conversion of binary data to BCD data.

STR = 1: Conversion of BCD data to binary data

Reset (RST)

RST = 0: Error output R1 is not reset.

RST = 1: Error output R1 is reset.

Execution command (ACT)

ACT = 0: The double-word data conversion instruction is not executed.

ACT = 1: The double-word data conversion instruction is executed.

Error output (R1)

R1 = 0:

Normal

R1 = 1:

Error

(15)SUBP 032 (Binary Comparison) RR after operation:

Ù

a) Function

The instruction executes comparison of the 1-, 2-, or 4-byte length binary data and
outputs the result of comparison. Both the input data and the data for comparison
must be the data of the specified length.

(b) Example

= 0: 1byte, = 1: 2bytes = 2: 4bytes