beautypg.com

Yasnac, Figure 1: placement of paradym-31 dll – Yaskawa YASNAC PC NC PLC Programming Manual User Manual

Page 202

background image

11 - 3

YASNAC PCNC PLC Programming Manual Chapter 11: YASNAC Paradym-31 DLL

11.3 Paradym-31 Communication Effectiveness and Ineffectiveness

In order to communicate with the Paradym-31, the following conditions must be satisfied.

CNC system number switch must be set to “4”.

Paradym-31 communication effectiveness parameter (pm5014 d5=1) must be ON.
When the pm5014 d5 is changed, the NC alarm “ALM0050: PARAM REQUIRING
POWER OFF”
is displayed. Therefore, it is necessary to turn on NC power after it has
been turned off.
Once the above conditions are satisfied, CNC device communication is automatically set.

Restrictions during Paradym-31 communication effectiveness:

Ladder display does not occur when the Paradym-31 communication is performed.
If the ladder display function key is pressed, the warning “P31 is being selected!” occurs.

11.4 Where is the DLL Placed?

The following diagram illustrates where the DLL is placed.

Paradym-31

Application

Communication
parameter set-up

functions

YASKAWA-made
DLL

Yaskawa DLL

Compiler/Linker

Sequence Download

Function

Sequence

Start/Stop

Contact Data

Obtain Function

YNCCOMP. DLL

Binary

C

o

m

m

u

n

ic

atio

n

C

o

m

m

u

n

ic

atio

n

C

o

m

m

u

n

ic

atio

n

YASNAC

YNCCOMP. DLL

Figure 1: Placement of Paradym-31 DLL