6 - 65

YASNAC PCNC PLC Programming Manual Chapter 6: PLC Instructions

(b) Example

(c) Control conditions

Designation of the data table size (number of bytes) (IPSHXX)

Designate the size of the data table by the number of bytes.

Designation of the start address of the data table (APSH#XXXX)

Designate the start address of the data table.

The data table can be created any place.

Designation of the address storing the I/O data (APSH#XXXX)

RW = 0:

The address where the output data are stored.

RW = 1:

The address where the input data are stored.

Designation of the address storing the number in the table (APSH#XXXX)

The data to be read or rewritten are designated by the number in the table.
Designate the address where this number is stored.

Designation of the data size (BYT)

BYT = 0: The data stored in the data table are 1-byte data.

BYT = 1: The data stored in the data table are 2-byte data.

Designation of read/write processing (RW)