YASNAC PCNC PLC Programming Manual Chapter 6: PLC Instructions

(14)MVI (Move Immediate) RR after operation: RR

Ù

(a) Function

The function transfers the numeric value to the register when the ST contact is ON (RR =
1). If the ST contact is OFF (RR = 0), the instruction is not executed.

(b) Format

(c) Explanation

An ST contact must be entered before the MVI instruction.

The MVI instruction is executed in intervals of “4 × n” msec while the ST contact is
ON.

(d) Example

(15)ADD (Add Register) RR after operation: RR

Ù

(a) Function

The function executes addition between the content in the resister R2 and the content in
register R1 when the ST contact is ON (RR = 1) and stores the result to register R2.

The content in register is R1 remains unchanged and the status of RR also remains
unchanged.

If the ST contact is OFF (RR = 0), the instruction is not executed.

(b) Format

B A Paradym31 Variable Name

A B Paradym31 Variable Name