6 - 13

YASNAC PCNC PLC Programming Manual Chapter 6: PLC Instructions

(10) STR-NOT (Store NOT) RR after operation: RR

Ù

(a) Function

Sets the contents of RR to stack and executes the LD-NOT instruction.

(b) Format

(c) Example

(11) AND-STR (AND Store) RR after operation: RR

Ù

(a) Function

Executes AND between RR and stack (ST0) and sets the result to RR.
Stacks shift to the left by one.

(b) Format

AND-STR