YASNAC PCNC PLC Programming Manual Chapter 4: Sequence Control Method

í SYMBOL

This defines the names for individual coils.

Definition is possible in up to 8 characters.

In the display of ladder, the first 5 characters of the specified symbol
name are displayed.

Registration capacity of the symbol makes is 5000.

Format: SYMBOL . . . . . ENDP

(b) Included files

Files shown below are examples of high-speed scan ladder, low-speed scan ladder,
conversion data, and message data that are included in the main file (YELAD-
FER.SRC). Pseudo instructions such as HIGHSEQUENCE, LOWSEQUENCE,
CONVERSION, MESSAGE, SYMBOL and ENDP must not be written in the
source files.They must be written in a main file.

LAD.HI

LAD.L01

LAD.L02

;*************************
**********

LD #10000
OUT#11000

-

;*************************
**********

LOWSEQUENCE
LD #14000
INR #1500

-

;*************************
**********

LD #14056
DST#1552, #1532, 0FFH

-

Out #14033