Yaskawa YASNAC PC NC PLC Programming Manual User Manual
Page 170

8 - 22
YASNAC PCNC PLC Programming Manual Chapter 8: Online Editing
8.4.5
Inputting Register Instructions
By keying in the first letter of register instruction, pop-up menu for the selection of the register
instruction appears on the screen.
(1) Items Given in Pop-up Menu
The items displayed in the pop-up menu are indicated in Table 8.3. In response to the
character keyed-in to the key buffer area, the corresponding list of register instructions is
displayed in the pop-up menu. Select the required instruction by moving the cursor on it
and press the [
WR
] key. The require register instruction can be written in this manner.
Table 8.4.5.1 List of Register Instructions Displayed in Pop-up Menu
Keyed-in
Character
Corresponding Register Instructions Displayed in Pop-up Menu
Quantity
A
ANI, ADI, ADD, ANR, ADC, ADDW, ADR, APSH
8
C
CLR, CMR, COI, CMP, CPI, CPR, CIR, CLRW, CMRW, CORW,
CPRW
11
D
DCR, DEC, DST, DIN, DIVW, DSTW, DCRW
7
I
INR, INRW, IPSH, IPSHD
4
M
MVI, MOV, MULW, MVIW, MCR,
5
S
SUB, SBI, SUBW, SET, SUBP3, SUBP4, SUBP5, SUBP6, SUBP7,
SUBP9, SUBP11, SUBP14, SUBP17, SUBP18, SUBP23, SUBP25,
SUBP27, SUBP31, SUBP32, SUBP34, SUBP35, SUBP36, SUBP37,
SUBP38, SUBP39, SUBP40
26
T
TIM, TMR, TPSH
3
O
ORR, ORI
2
X
XTI, XRR, XOR, XNR
4