YASNAC PCNC PLC Programming Manual Chapter 6: PLC Instructions

(c) Control conditions

Designation of the data code area (APSH#XXXX)

Designate the address of the code to be decoded.

Two bytes are used.

Designation of the start address of the decode table (APSHXXXX)

Designate the start address of the table to be decoded.

Maximum decode number (IPSHXXXX)

Designate the maximum number of the decode bits.

Designation of the size of the data in the decode area (BYT).

LD = 0:

The size if the data in the conversion table is 1 byte.

LD = 0:

The size if the data in the conversion table is 2 byte.

Reset (RST)

RST =0:

Error output R1 is not reset.

RST = 1: Error output R1 is reset.

Execution command (ACT)

ACT = 0: The binary decode instruction is executed. R1 remains unchanged.

ACT = 1: The binary decode instruction is to executed.

Error output (R1)

R1 = 0:

Normal

R1 = 1:

Error

A numeric value greater than the table size is set.