YASNAC PCNC PLC Programming Manual Chapter 6: PLC Instructions

(36)MVIW (Move Immediate Word Register) RR after operation: RR-

(a) Function

The instruction transfers the numeric value to the register when the ST content is ON
(RR = 1).

If the ST contact is OFF (RR = 0), the MVIW instruction is not executed.

(b) Format

(c) Explanation

A ST contact must be entered before the MVIW instruction.

The MVIW instruction is executed in intervals of “4 × n” msec while the ST contact
is ON.

(d) Example

(37)DSTW (Data Store Word Register) RR after operation: RR-

(a) Function

The instruction executes AND between the content of WR1 and the numeric value when
the ST contact is ON (RR = 1) and stores the result to WR2. The content of the register
(WR1) remains unchanged before and after the execution of the instruction.

If the ST contact is OFF (RR = 0), the DSTW instruction is not executed.

(b) Format

B C

A