beautypg.com

Yaskawa YASNAC PC NC PLC Programming Manual User Manual

Page 30

background image

5 - 7

YASNAC PCNC PLC Programming Manual Chapter 5: Address Numbers And Map

(7) Addresses of Timers (#1300 to #1399 and #1700 to #1799)

For the timers, addresses #1300 to #1399 and #1700 to #1799 are assigned.

One address number corresponds to a timer.

Example:

The number of available timers and timer setting units are indicated below.

Table 5.1 Available Timer and Setting Units

An example of a timer symbol is indicated below.

Example:

Address No.

Timer Type

Number of Timers

#1700 to #1709, #1760 to #1769
#1300 to #1309, #1360 to #1369

1 = 8 msec

40

#1710 to #1729, #1790 to #1799
#1310 to #1329, #1390 to #1399

1 = 0.1 sec

60

#1730 to #1749, #1780 to #1789
#1330 to #1349, #1380 to #1389

1 = 50 msec

60

#1750 to #1759, #1350 to #1359

1 = 1 sec

20

#1770 to #1773, #1370 to #1373

1 = 1 min.

8