beautypg.com

Yaskawa YASNAC PC NC PLC Programming Manual User Manual

Page 20

background image

4 - 3

YASNAC PCNC PLC Programming Manual Chapter 4: Sequence Control Method

4.2 Operation of Sequence Program

4.2.1

Sequence Program
Length of time necessary for the execution of one cycle of a sequence program is called the scan
time. The scan time of this model of PLC is indicated below.

High-speed processing scan time: 8 msec

Low-speed processing scan time: 8 msec × n

This means, with this PLC, the sequence program can be processed by dividing it into a high
speed processing part and low-speed processing part. Therefore, the sequence program must be
written in the format indicated below.

Fig. 4.2 Sequence Program Format

As indicated above, the sequence program that requires high-speed processing should be entered
first and the sequence program for which low-speed processing is acceptable should be entered
after that.

4.2.2

Operation

The operation time chart of PCNC sequence program is indicated below.

Fig. 4.3 PCNC Operation Time Chart