beautypg.com

Yaskawa YASNAC PC NC PLC Programming Manual User Manual

Page 143

background image

7 - 16

YASNAC PCNC PLC Programming Manual Chapter 4: Sequence Control Method

(5) Time Check

The compiler checks the range of registers used for timers.

It also checks the interference in the addresses of the timers (#1700s and #1300s).

(6) Label Check

The compiler checks the ADR label names for overlapped definition.

The correspondence between the JMP and ADR is also cheeked.

(7) STR and AND-STR Check

The compiler checks the correspondence between the STR (STR-NOT) and AND-STR
(OR-STR)

(8) SUBP Calling Sequence Check

The compiler checks the correspondence between the SUBP and PUSH (APSH,
TPSH, IPSHD).

It also checks the correspondence between the SUBP and STR.

(9) Existence Check for RTH and RET

The compiler checks the RTH and RET for the following:

Only one RTH exists.

Either RET or RTI exists.