beautypg.com

HEIDENHAIN TNC 320 (34055x-06) Cycle programming User Manual

Page 376

background image

Touch Probe Cycles: Special Functions

17.5

CALIBRATE TS (Cycle 460, DIN/ISO: G460)

17

376

TNC 320 | User's Manual Cycle Programming | 5/2013

Reference angle Q380 (absolute): Reference
angle (basic rotation) for measuring the measuring
points in the active workpiece coordinate system.
Defining a reference angle can considerably enlarge
the measuring range of an axis. Input range 0 to
360.0000

Calibrate length (0/1) Q433: Define whether the
TNC is to calibrate the touch probe length after
radius calibration, as well:

0

: Do not calibrate touch probe length

1

: Calibrate touch probe length

Datum for length Q434 (absolute): Coordinate of
the calibration sphere center. The definition is only
required if length calibration is to be carried out.
Input range -99999.9999 to 99999.9999