Cycle parameters, Selecting a datum table in the part program – HEIDENHAIN TNC 320 (34055x-06) Cycle programming User Manual
Page 223

DATUM SHIFT with datum tables (Cycle 7, DIN/ISO: G53)
11.3
11
TNC 320 | User's Manual Cycle Programming | 5/2013
223
If you are using datum shifts with datum tables, then
use the
SEL TABLE function to activate the desired
datum table from the NC program.
If you work without
SEL TABLE, then you must
activate the desired datum table before the test
run or the program run. (This applies also to the
programming graphics).
Use the file management to select the desired
table for a test run in the
Test Run operating
mode: The table receives the status S.
Use the file management in a program run mode
to select the desired table for program run: The
table receives the status M.
The coordinate values from datum tables are only
effective with absolute coordinate values.
New lines can only be inserted at the end of the
table.
If you create datum tables, the file name has to start
with a letter.
Cycle parameters
Datum shift: Enter the number of the datum from
the datum table or a Q parameter. If you enter a Q
parameter, the TNC activates the datum number
entered in the Q parameter. Input range: 0 to 9999
NC blocks
77 CYCL DEF 7.0 DATUM SHIFT
78 CYCL DEF 7.1 #5
Selecting a datum table in the part program
With the
SEL TABLE function you select the table from which the
TNC takes the datums:
Select the functions for program call: Press the
PGM CALL key
Press the DATUM TABLE soft key
Select the complete path name of the datum table
or the file with the SELECT soft key and confirm
your entry with the END key
Program a
SEL TABLE block before Cycle 7 Datum
Shift.
A datum table selected with
SEL TABLE remains
active until you select another datum table with
SEL
TABLE or through PGM MGT.