Touch Probe Cycles: Automatic Workpiece Inspection

16.7 MEASURE RECTANGLE INSIDE (Cycle 423, DIN/ISO: G423)

16

348

TNC 320 | User's Manual Cycle Programming | 5/2013

Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999

Traversing to clearance height Q301: definition
of how the touch probe is to move between the
measuring points:

0

: Move at measuring height between measuring

points

1

: Move at clearance height between measuring

points

Max. size limit 1st side length Q284: Maximum
permissible length of the pocket. Input range 0 to
99999.9999

Min. size limit 1st side length Q285: Minimum
permissible length of the pocket. Input range 0 to
99999.9999

Max. size limit 2nd side length Q286: Maximum
permissible width of the pocket. Input range 0 to
99999.9999

Min. size limit 2nd side length Q287: Minimum
permissible width of the pocket. Input range 0 to
99999.9999

Tolerance for center 1st axis Q279: Permissible
position deviation in the reference axis of the
working plane. Input range 0 to 99999.9999

Tolerance for center 2nd axis Q280: Permissible
position deviation in the minor axis of the working
plane. Input range 0 to 99999.9999

NC blocks

5 TCH PROBE 423 MEAS. RECTAN.

INSIDE

Q273=+50

;CENTER IN 1ST AXIS

Q274=+50

;CENTER IN 2ND AXIS

Q282=80

;FIRST SIDE LENGTH

Q283=60

;2ND SIDE LENGTH

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+10

;CLEARANCE HEIGHT

Q301=1

;MOVE TO CLEARANCE

Q284=0

;MAX. LIMIT 1ST SIDE

Q285=0

;MIN. LIMIT 1ST SIDE

Q286=0

;MAX. LIMIT 2ND SIDE

Q287=0

;MIN. LIMIT 2ND SIDE

Q279=0

;TOLERANCE 1ST

CENTER

Q280=0

;TOLERANCE 2ND

CENTER

Q281=1

;MEASURING LOG

Q309=0

;PGM STOP IF ERROR

Q330=0

;TOOL