Cycle parameters – HEIDENHAIN TNC 320 (34055x-06) Cycle programming User Manual
Page 305

DATUM FROM OUTSIDE OF CIRCLE (Cycle 413, DIN/ISO: G413) 15.7
15
TNC 320 | User's Manual Cycle Programming | 5/2013
305
Cycle parameters
Center in 1st axis Q321 (absolute): Center of the
stud in the reference axis of the working plane.
Input range -99999.9999 to 99999.9999
Center in 2nd axis Q322 (absolute): Center of the
stud in the minor axis of the working plane. If you
program Q322 = 0, the TNC aligns the hole center
to the positive Y axis. If you program Q322 not
equal to 0, then the TNC aligns the hole center to
the nominal position. Input range -99999.9999 to
99999.9999
Nominal diameter Q262: Approximate diameter of
the stud. Enter a value that is more likely to be too
large than too small. Input range 0 to 99999.9999
Starting angle Q325 (absolute): Angle between the
reference axis of the working plane and the first
touch point. Input range -360.000 to 360.000
Stepping angle Q247 (incremental): Angle between
two measuring points. The algebraic sign of the
stepping angle determines the direction of rotation
(negative = clockwise) in which the touch probe
moves to the next measuring point. If you wish to
probe a circular arc instead of a complete circle,
then program the stepping angle to be less than
90°. Input range -120.000 to 120.000
Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point) in the touch probe axis in which
the measurement is to be made. Input range
-99999.9999 to 99999.9999
Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to
SET_UP (touch probe table). Input
range 0 to 99999.9999
Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999
Traversing to clearance height Q301: definition
of how the touch probe is to move between the
measuring points:
0
: Move at measuring height between measuring
points
1
: Move at clearance height between measuring
points
Datum number in table Q305: Enter the number
in the datum/preset table in which the TNC is to
save the coordinates of the stud center. If you enter
Q305=0, the TNC automatically sets the display
so that the new datum is on the stud center. Input
range 0 to 2999
NC blocks
5 TCH PROBE 413 DATUM OUTSIDE
CIRCLE
Q321=+50
;CENTER IN 1ST AXIS
Q322=+50
;CENTER IN 2ND AXIS
Q262=75
;NOMINAL DIAMETER
Q325=+0
;STARTING ANGLE
Q247=+60
;STEPPING ANGLE
Q261=-5
;MEASURING HEIGHT
Q320=0
;SET-UP CLEARANCE
Q260=+20
;CLEARANCE HEIGHT
Q301=0
;MOVE TO CLEARANCE
Q305=15
;NO. IN TABLE
Q331=+0
;DATUM
Q332=+0
;DATUM
Q303=+1
;MEAS. VALUE
TRANSFER
Q381=1
;PROBE IN TS AXIS
Q382=+85
;1ST CO. FOR TS AXIS
Q383=+50
;2ND CO. FOR TS AXIS
Q384=+0
;3RD CO. FOR TS AXIS
Q333=+1
;DATUM
Q423=4
;NO. OF PROBE POINTS
Q365=1
;TYPE OF TRAVERSE